Iron removal equipment G-SAND-3000 2,0-2,5 m³/st

999,00 €
~ Removes iron (Fe 2+ , Fe 3+ )
~ Reduces manganese (Mn 2+ , Mn 3+ )
~ Reduces hydrogen sulfide odors

Dear customer!
In order to place an order and make sure that the chosen equipment meets your needs, before purchasing, we recommend sending the results of water analyzes and consulting with our specialist by filling out the contact form or calling mob. 29349862.

Application of the equipment

            Mostly, the equipment is used to purify water from iron (Fe2+), and additional equipment reduces manganese and hydrogen sulfide.

- Operating principle

            The filtering material “Manganese greensand” sand is located in the filtration tank (column) of the equipment. This specific sand is coated with manganese dioxide, and is able to reduce hydrogen sulfide, oxidize and filter iron and manganese in water.

Therefore, the consumer is provided with purified water. When the capacity of the filtering material “Manganese greensand” is worn out, it must be rinsed and renewed by regenerating with a potassium permanganate solution. With the help of the control mechanism, the device provides this rinsing and regeneration in a fully automatic mode. For the regeneration of the equipment, reagent Potassium permanganate (blue grains) is required. The reagent should be topped up relatively infrequently, approximately once every two to four months, depending on water consumption.

            The equipment is recommended to be used especially in cases where there is a higher number of bacteria in the water, as during the regeneration process, potassium permanganate also provides partial disinfection of the equipment and the filtering environment.

Important! Rinsing wastewater must not be discharged into biological sewage systems!

The efficiency of purification

Elements:

Iron

(Fe 2+)

mg/l       

Manganese

(Mn 2+ )

mg/l

Hydrogen sulfide

(H2S) mg/l

Water purification capacity:

14

5

3

Water purification level:

<0,2

<0,05

<0,05

 

Recommended pH level in water: 6,2-8,5 

Components and manufacturers:

            The most essential components of the equipment are control mechanisms and fillings. With great experience in water purification, we have gained complete confidence in the quality, safety and durability of the components.

            The water treatment equipment of this series is assembled from: "Clack WSEI" manufactured in the USA; "WSCI" mechanisms, quartz sand "Dansk kvarts industri" (Denmark), as well as filtration materials "Manganese Greensand+".

Clack logo   greensand plus logo

Technical parameters:

MODEL:

G-SAND

1000

G-SAND

1500

G-SAND

2000

G-SAND

3000

G-SAND

4000

G-SAND

6000

Equipment purification performance (m³h)

0,8-1,0

1,0 - 1,5

1,5 - 1,8

2,0 - 2,5

2,5 - 3,0

3,0-3,5

Maximum flow (m³h)

4,0m³h

Operating working pressure

(bar)

2,5-6

3-6

Regeneration time (min)

80-90

80-95

90-105

90-105

110-120

110-125

Total amount of waste water per regeneration (m³)

0,25 - 0,33

0,28 - 0,38

0,42 - 0,49

0,49 - 0,60

0,60 - 0,75

0,70 - 0,85

Flush flow rate

Backwash cycle (l/min)

15

15

20

24

28

28

column size with control unit (cm)

Height/diameter

Volume (litres)

134 x 26,5

51

160 x 26,5

62

155 x 32

87

160 x 34

105

190 x 38

150

190 x 43

195

Total amount of filling in the tank (litres)

31

42

55

70

90

120

Size of the reagent tank (cm)

Height/diameter/length/volume (litres)

42 x Ø27

20l

Addition of water – dimensions of input and output

1''- external threads

1 ¼’’ - external threads

Dimensions of the sewage connection

¾ - external threads

Electricity connection

220 - 240V -12V

Operating temperature

+4 - +30ºC

Recommended area for installation (cm):

Height/width/length

150x45x60

180x45x60

180x50x70

180x55x70

210x60x90

210x65x90

  • The performance of the equipment is affected by the quality of the water, so it must be taken into account, that the worse the water quality, the slower the purification rate.
  • The frequency of rinsing is calculated for each customer individually, which depends on the quality of the water to be cleaned (content of iron, manganese, etc) and the selected equipment model.
  • The total amount of wastewater per regeneration also depends on water pressure, pipe diameters, etc.
  • The duration of rinsing depends on the adjustments that are set for each object individually based on water quality.


Operation

  • It is necessary to independently and regularly monitor the replenishment of the reagent “Potassium permanganate”. The frequency of replenishment depends on the frequency of regenerations. In standard situations, the reagent is added approximately once in 3 months, adding approximately 2-3 kg.
  • It is recommended to perform equipment maintenance once a year.
  • Periodically, every 3-10 years, it will be necessary to change the filling of the equipment. The frequency of change depends on the quality of the water to be treated, the flushing efficiency of the equipment and the water consumed.


Warranty

The total warranty of the equipment is 3 years.

Reviews

There are yet no reviews for this product.

Working hours

Monday:         9:00 - 18:00
Tuesday:        9:00 - 18:00
Wednesday:   9:00 - 18:00
Thursday:       9:00 - 18:00
Friday:            9:00 - 17:00
Saturday and sunday: Days off

Company details

"UDENS BUVE" Ltd
Reg.Nr.: 44103048783
VAT Nr.: LV4410304878
Legal address: Ropazu street 41-11, Riga, LV-1006

Actual address: Kalnciema str 87, Riga, LV-1046

Contacts

Office mob.: +371 29349862
E-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.
Project manager: +371 28318246 
Service: +371 22301342
Marketing: +371 29555817
E-pasts: This email address is being protected from spambots. You need JavaScript enabled to view it.
CONTACT FORM

Visa Mastercard

Paysera logo